DE Electric Actuator Voltages, MC and SMC Proportional Control, and Fast Open-Close KS001 and KS002

DE series electric actuator voltages, MC and SMC proportional control, and KS001 and KS002 fast open-close models, photo 1

At a Glance

Topic: voltage types of electric actuators, MC and SMC proportional control, and the fast open-close KS001 and KS002

Voltage: AC single-phase 110V and 220V, AC three-phase 380V and 440V, DC 24V (varies by model)

24V DC control board: 2-wire C2 and 3-wire C3 options (some models)

Proportional control: MC takes a single 4~20mA signal; SMC also accepts voltage signals and can run on 24V DC power

Fast open-close: KS001 (10Nm) and KS002 (25Nm), full stroke within 1 second, DC 24V and 12V power

Products covered: VALVEPARK DE series electric actuators and the fast open-close KS

An electric actuator is a drive unit that turns a valve through 90° with a motor to open and close it, and it is mounted on ball valves and butterfly valves. The VALVEPARK DE series has an ISO 5211 (actuator mounting flange standard) mounting face, so it can sit directly on a valve, and it can be turned by manual operation when there is no power. This article sorts out the supply voltage, the 24V DC control board option, the MC and SMC proportional control options that adjust the valve to intermediate positions, and the KS001 and KS002 fast open-close models that move the valve within 1 second, by site condition.

DE series electric actuator voltages, MC and SMC proportional control, and KS001 and KS002 fast open-close models, photo 2

VALVEPARK DE series electric actuator

There are three things to decide first when choosing: the voltage of the site power, the control method (open and close only, or adjustment to intermediate positions), and the operating time the valve takes to move. They are covered in that order below.

What Voltages Are Available

The DE series supports three kinds of power, AC single-phase, AC three-phase and DC, and the models you can choose depend on the power type. Power wiring is connected by opening only the terminal block (the place where wires are connected) cover, without opening the whole body.

DE series electric actuator voltages, MC and SMC proportional control, and KS001 and KS002 fast open-close models, photo 3

Wiring section inside the DE series with the terminal block cover open

PowerVoltageApplicable models
AC single-phase110V, 220V (50/60Hz)All models DE002 to DE120 (the DE005 covers AC 100~250V in a single version)
AC three-phase380V, 440VDE016, DE028, DE040, DE050, DE080, DE120
DC24VDE002 to DE040

Model range by power type

The force each model can deliver (maximum torque) also differs: 24V DC is available up to the DE040 (400Nm), and the larger DE050 and above come only as AC-powered models.

ModelMax. torqueAC single-phaseAC three-phaseDC 24V
DE00220Nm○-○
DE00440Nm○-○
DE00550Nm○ (100~250V)-○
DE00660Nm○-○
DE00880Nm○-○
DE010100Nm○-○
DE016160Nm○○○
DE028280Nm○○○
DE040400Nm○○○
DE050500Nm○○-
DE080800Nm○○-
DE1201200Nm○○-

Some DC 24V models have a board option (2-wire C2, 3-wire C3) that controls opening and closing. If it is hard to build a separate relay circuit on site, please contact us.


How MC and SMC Proportional Control Differ

An ON-OFF actuator only opens or closes the valve fully, while proportional control holds the valve at an intermediate position that matches the size of the signal sent by the controller. It is used where flow or pressure is adjusted by a signal, and the DE series offers two options, MC and SMC. The MC option contains a control board, on which you set the behavior when the input signal is lost (open, close or stop), the resolution and the output signal.

DE series electric actuator voltages, MC and SMC proportional control, and KS001 and KS002 fast open-close models, photo 4

MC control board (for the DE005). The red boxes mark the positions of the operation buttons, input signal fault setting, output signal setting, resolution setting and status LED

ItemMCSMC
Input signal4~20mA4~20mA and voltage signals of 0~5V, 0~10V, 1~5V, 2~10V
PowerAC single-phaseAC single-phase, DC 24V
Selectable modelsAll models DE002 to DE120Single-phase: all models DE002 to DE120; 24V DC: DE002 to DE040

MC for 4~20mA, SMC for voltage signals

If you know the signal your site controller (a PLC or control panel) sends out and the power you have, one of the two is decided.


Fast Open-Close KS001 and KS002: Moving a Valve Within 1 Second

The operating time of the DE series is 10 to 51 seconds depending on the model and torque, and where a valve must move within 1 second, the fast open-close KS model is used. It completes the full stroke from open to closed within 1 second.

ModelTorquePowerMounting faceShaft
KS00110NmDC 24V, DC 12VISO 5211 F03, F05, F0714*14
KS00225NmDC 24V, DC 12VISO 5211 F03, F05, F0714*14

Open-close within 1 second, DC 24V and 12V power

The motor is a brushless BLDC type and can run at 100% continuous duty.

Fast open-close is used in environments that need immediate valve control, such as data centers and defense, and also in semiconductor, fire protection, special-purpose vehicle and battery applications. Torque is 10Nm for the KS001 and 25Nm for the KS002, so choose a valve that needs more force from the DE series.


Choosing a Model by Site Condition

Site conditionModel to look atReason
AC single-phase 220V or 110V, open and close onlyDE series (ON-OFF)All DE002 to DE120 support single-phase; the model is set by valve bore and torque
AC three-phase 380V or 440V, large valveDE016 and aboveMaximum torque ranges from 160Nm to 1200Nm
Only 24V DC in the control panelDE002 to DE040Maximum torque ranges from 20Nm to 400Nm
Open-close control on 24V DC24V DC control board options C2, C3 (some models)Pick 2-wire or 3-wire to match the site wiring
Position control by 4~20mA signalMCAll models can be selected at AC single-phase sites; 24V DC sites go to SMC
Control by voltage signal, or 24V DC powerSMCAccepts both 4~20mA and voltage signals
Open-close within 1 secondKS001, KS002Full stroke within 1 second

If you look up valves and actuators separately, you have to check one by one whether the mounting face and torque match. VALVEPARK offers the MC and SMC proportional control options on the DE series and has selection tables by bore for ball valves and butterfly valves, so you can start from the model that fits your valve type and bore.


Common Questions Before Adoption

Q. We only have 24V DC power. Can it be used on a large valve too?

A. Only up to the DE040 (maximum torque 400Nm). The larger DE050 and above are AC-powered models, so tell us the valve bore and pressure and we will check whether the torque fits.

Q. Can the valve be turned by hand during a power failure?

A. Yes. The DE series has manual operation, so the valve can be turned without power, with a wrench or a handwheel depending on the model.

Q. Can it be mounted directly on the valve we already use?

A. It can be mounted only if the valve's mounting face and shaft dimensions match. The DE series mounting faces are ISO 5211 F03 to F14 and each model supports different standards, so tell us the valve's mounting face standard and shaft dimensions and we will check the matching model.

Q. Can the KS001 and KS002 be used on AC power?

A. The standard power is DC 24V and DC 12V. If your site power is AC, we need to check whether a configuration is possible, so please tell us your power conditions.

Q. Can they be used in explosion-proof environments?

A. Explosion-proof types are a separate line. They are Ex d IIB T4 (flameproof enclosure marking) and IP67, with DC 24V and AC 110V and 220V specifications. Please tell us the explosion-proof zone classification of the installation site.


Information to Prepare When Requesting a Quote

Tell us the valve and power conditions you use and we will advise you. It is fine if some items are not yet decided.

1. Valve type and bore: ball valve or butterfly valve, bore, and mounting face standard if known

2. Power: AC single-phase or three-phase voltage, or DC 24V or 12V (for DC 24V, whether open-close wiring is 2-wire or 3-wire)

3. Control method: open and close only (ON-OFF) or proportional control (signal type: 4~20mA, voltage), and whether open-close within 1 second is needed

4. Installation environment: indoor or outdoor, whether it is an explosion-proof zone

5. Quantity and required timing

If you need an electric actuator that fits your valve type and bore, power and control method, please contact us at the address below.

Purchase and Inquiries

VALVEPARK Official Contact

Buying piping materials becomes the easiest and fastest task.

Emailsales@valvepark.com
Phone1666-0215
KakaoTalk ChannelChat on KakaoTalk
WebsiteGo to the VALVEPARK website
Smart StoreGo to the VALVEPARK Smart Store

DE series electric actuator product page: https://www.valvepark.com/valvepark/electric-actuator/electric-actuator-de-series?utm_source=naver_blog&utm_medium=blog&utm_campaign=electric-actuator-voltage-mc-smc-ks

DE Electric Actuator Voltages, MC and SMC Proportional Control, and Fast Open-Close KS001 and KS002