Products: VALVEPARK micro pressure regulators MPR01 (micro pressure reducing) and MPR02 (micro pressure relief)
Operation: self-acting, no external power required
Controlled variable: pressure inside the tank (set range MPR01 0.5~6.0 kPa(G), MPR02 0.5~4.0 kPa(G))
Specifications: 1/2"~4" (15A~100A), flange (RF, FM), BW and threaded, ASME Class 150~300 (PN16~40)
Tank blanketing (a method that protects the stored medium by filling the top of the tank with an inert gas such as nitrogen) systems must hold the tank pressure at a few kPa. The VALVEPARK MPR01 and MPR02 are self-acting micro pressure regulators that work without electricity or compressed air. The one that holds the outlet pressure constant is the MPR01 (micro pressure reducing), and the one that opens and relieves when the tank pressure exceeds the set value is the MPR02 (micro pressure relief).
In a tank blanketing system, keeping the pressure inside the tank stable is what protects the stored medium, and the tank can be damaged if the pressure rises excessively. A micro pressure regulator controls low gas pressure in the kPa range (micro pressure), and it is designed in particular for tank blanketing systems such as the nitrogen sealing systems of medium and large storage tanks.
Taking the MPR01 as the reference, the structure is divided into two parts: an actuator containing the spring, diaphragm and other parts, and a main valve containing the body, seat, plug and other parts.
MPR01 is the model name of the Micro Pressure Reducing Regulator, and MPR02 is the model name of the Micro Pressure Relief Regulator.
Reducing is the MPR01, relief is the MPR02
MPR01 micro pressure reducing regulator
MPR02 micro pressure relief regulator
| Model | Role | Set pressure range |
|---|---|---|
| MPR01 micro pressure reducing regulator | Holds outlet pressure | 0.5~6.0 kPa(G) |
| MPR02 micro pressure relief regulator | Relieves overpressure above the set value | 0.5~4.0 kPa(G) |
The MPR01 controls the outlet pressure automatically, and its minimum control pressure is 0.5 kPa. The usual inlet pressure range is 2.0~8.0 bar(G).
The MPR01 can be combined with a breather valve or a nitrogen relief regulator to form a tank protection system. A spring-loaded pressure reducing regulator generally opens fully if the diaphragm fails. First check that the downstream piping and the tank can withstand the inlet pressure.
It is not suited to a tank whose set pressure exceeds 6.0 kPa(G) for the MPR01 or 4.0 kPa(G) for the MPR02. The same goes for a case that needs a deviation narrower than the control accuracy of ±15%, so check the set conditions first.
| Item | MPR01 and MPR02 (common) |
|---|---|
| Size | 1/2"~4" (15A~100A) |
| Connection | Flange (RF, FM), butt weld (BW), threaded |
| Pressure class | ASME Class 150~300 (PN16~40) |
| Control accuracy | ±15% |
| Body material | Carbon steel, stainless steel, alloy steel, duplex stainless steel |
| Casing material | Carbon steel, stainless steel |
| Diaphragm material | NBR, FKM, EPDM |
| Control line | Stainless steel φ10×1 mm, fitting M14×1.5 |
| Options | Diaphragm NBR, FKM, EPDM / seat leakage ANSI Class IV or VI |
The flow characteristic is quick opening, and the allowable leakage, based on air at an inlet pressure of 1.0 bar, increases as the size increases. The values are the same for both models.
| Size | 15A | 20A | 25A | 32A | 40A | 50A | 65A | 80A | 100A |
|---|---|---|---|---|---|---|---|---|---|
| Allowable leakage (bubbles/min) | 1 | 2 | 3 | 4 | 4 | 6 | 6 | 11 | 11 |
| Size | H | ΦR | L | Weight (kg) |
|---|---|---|---|---|
| 15A | 320 | 280 | 160 | 18.0 |
| 20A | 370 | 280 | 160 | 21.0 |
| 25A | 390 | 280 | 160 | 26.0 |
| 32A | 400 | 280 | 230 | 32.0 |
| 40A | 410 | 280 | 230 | 40.0 |
| 50A | 438 | 280 | 230 | 47.0 |
| 65A | 460 | 280 | 290 | 60.0 |
| 80A | 500 | 280 | 310 | 65.0 |
| 100A | 520 | 280 | 350 | 71.0 |
Unit: mm, tolerance ±0.5 mm
Q. Can installing only the MPR01 prevent tank overpressure?
A. The MPR01 alone cannot prevent it. Pressure above the set value is released by a relief device such as the MPR02 or a breather valve, so configure them together.
Q. Can it replace an existing micro pressure regulator in the same position?
A. Replacement can be considered when the size, pressure class and connection type are the same and the L value in the dimension table matches. The set pressure range and the diaphragm material are checked separately.
Q. Can the seat leakage class and diaphragm material be chosen?
A. Yes. As options, the seat leakage class is ANSI Class IV or VI, and the diaphragm material is selected from NBR, FKM and EPDM.
1. Tank conditions: stored medium, blanketing gas (such as nitrogen), tank size and relief device configuration
2. Model: whichever is needed of the MPR01 for pressure reducing and the MPR02 for relief, or both
3. Size and connection: bore (A), whichever of flange (RF, FM), weld or threaded is needed, and pressure class (ASME Class 150 or 300)
4. Pressure conditions: set pressure (kPa(G)), inlet pressure (bar(G)), required flow rate
5. Options: diaphragm material, seat leakage class, medium and operating temperature
Other models in the same regulator line are introduced by purpose: PRR01 and PRR02 for pipeline pressure control, PDRC01 and PDRO01 for differential pressure control, and TR01 and TR02 for temperature control.
Purchase and Inquiries
| sales@valvepark.com | |
| Phone | 1666-0215 |
| KakaoTalk Channel | Chat on KakaoTalk |