Model: ECG
A common controller can operate electric actuators of different models and sizes. ECG-A automatically reads actuator information to reduce initial setup work.
| Applicable Actuators (ECG-A) | EJSG, EBS-G, EBR-G, GSSD2, GSTK, GSTG, GSTS, GSTL |
| Configuration Tool (ECG-A) | PC configuration software (S-Tools) |
| Connection cable (ECG-A) | Connection cable: USB cable (mini-B) |
| External Interface / Parallel I/O specifications (ECG-A) | 24 VDC ±10%, max. 13 I/O points each, max. cable length 10 m |
| External Interface / Field network specifications (ECG-A) | IO-Link, CC-Link, EtherCAT, EtherNet/IP |
| Power supply voltage / Control power supply (ECG-A) | 24 VDC ±10% |
| Power supply voltage / Motive power supply (ECG-A) | 24 VDC ±10% |
| Current Consumption / Control power supply (ECG-A) | 0.4 A or less |
| Brake current consumption (ECG-A) | 0.4 A or less |
| Insulation Resistance (ECG-A) | 10 MΩ or more at 500 VDC |
| Dielectric Strength (ECG-A) | 500 VAC for 1 minute |
| Operating Ambient Temperature (ECG-A) | 0 to 40°C no freezing |
| Operating Ambient Humidity (ECG-A) | 35 to 80% RH no condensation |
| Storage Ambient Temperature (ECG-A) | -10 to 50°C no freezing |
| Protection Structure (ECG-A) | IP20 |