Antibacterial / Bacteria Removing Filter

Model: SFC-FP2 / SFS-FP2

SFC-FP2 combines antibacterial and bacteria-removing filters, while SFS-FP2 is an inline bacteria-removing filter. Both series can be used with compressed air, nitrogen gas and carbon dioxide.

Features

Antibacterial / Bacteria Removing Filter SFC-FP2 / SFS-FP2Antibacterial / Bacteria Removing Filter SFC-FP2 / SFS-FP2 2

Specifications

Operating FluidCompressed air, nitrogen gas (N2), and carbon dioxide (CO2)
SFC Operating Pressure Range (MPa)0.1 to 1.0
SFC Proof pressure (MPa)1.5
Differential resistant pressure (MPa)0.5
Ambient/Fluid Temperatures (°C)5 to 45
SFC Filtration Rating (µm)0.01 (Removal Efficiency 99.99%)
SFC307 Max. processing flow rate (L/min (ANR))300
SFC407 Max. processing flow rate (L/min (ANR))500
SFC807 Max. processing flow rate (L/min (ANR))1100
SFC Standard AccessoriesMaintenance Sticker (Included)
Element Replacement1 year (6000 hours) or pressure drop 0.1 MPa
SFS Resin Type Operating Pressure (MPa)-0.095 to 0.99
SFS Stainless Type Operating Pressure (MPa)-0.095 to 1.5 (compressed air), -0.095 to 0.99 (N2, CO2)
SFS Filtration (µm)0.01 (Removal Efficiency 99.99 %)
SFS Assembly/Inspection/PackagingIntegrated Production in Clean Room
SFS CleaningDegreasing Cleaning
Max. processing flow rate primary pressure0.7 MPa

Request a Quote