Electric flow rate adjusting valve

Model: MNV

This electric needle valve uses a 2-phase stepper motor to adjust flow. The fluid temperature range is 20 to 195°C and the working pressure range is 0 to 0.2 MPa.

Features

Electric flow rate adjusting valve MNVElectric flow rate adjusting valve MNV 2

Specifications

Working fluidChemical liquids, pure water
Fluid temperature (°C)20 to 195
Proof pressure (MPa)0.5
Working pressure (A→B) (MPa)0 to 0.2
Fluid differential pressure (kPa)5 to 200 (differential pressure between ports A and B)
Setting range0 to 600step (motor drive step)
Operating ambient temperature (°C)20 to 100
Operating ambient humidity (%RH)20 to 85 (no condensation)
Storage ambient temperature (°C)0 to 60
Mounting orientationUnrestricted
Orifice size (mm)ø3.4
Degree of protectionWaterproof (IP65 or equivalent)
Weight (kg)0.51
Motor type2-phase stepper motor (bipolar)
Drive methodFull step (step angle: 1.8°)
Rated drive current (mA/phase)350
Drive speed (pps)650
Sensor power supply voltage24 VDC ±10% Ripple (P-P) 10[%] or less
Purge flow rate (L/min)15 to 30
Purge port sizeIN port: Rc1/8, EXH port: Rc1/8

Request a Quote