Model: HCM
This double-acting cylinder uses compressed air and operates at 50 to 2000 mm/s within the allowable absorption energy. It has an air cushion and a recommended stroke of 300 mm or more.
| Actuation method | Double Acting Type |
| Operating Fluid | Compressed Air |
| Max Operating Pressure (MPa) | 1.0 |
| Min Operating Pressure (MPa) | 0.15 |
| Proof Pressure (MPa) | 1.6 |
| Ambient Temperature (°C) | -10 to 60 (No freezing) |
| Operating Piston Speed (mm/s) | 50 to 2000 (Use within the allowable absorption energy.) |
| Cushion | With Air Cushion |
| Lubrication | Not Required (When lubricating, use turbine oil Class 1 ISO VG32) |
| Min Stroke (mm) | 150 |
| Recommended Stroke (mm) | 300 or more |
| Stroke (mm), ø20 to ø32 | 200 to 700 |
| Stroke (mm), ø40 to ø63 | 200 to 1000 |