Model: MVC
This compact cylinder integrates a cylinder and a vacuum suction pad for handling electronic and precision parts. Its vacuum port is located on the cylinder body, so the tube is not pulled during cylinder operation.
| Actuation method | Double Acting Type |
| Operating Fluid | Compressed Air |
| Max Operating Pressure (MPa) | 0.7 |
| Min Operating Pressure (MPa), ø6 | 0.15 |
| Min Operating Pressure (MPa), ø10 | 0.1 |
| Proof Pressure (MPa) | 1.05 |
| Vacuum port pressure | -101 KPa to 0.6 MPa |
| Ambient Temperature (°C) | 0 to 60 (however, no freezing) |
| Port Size, ø6 | M3 |
| Port Size, ø10 | M5 |
| Operating Piston Speed (mm/s) | 50 to 500 |
| Cushion | Rubber Cushion |
| Non-rotating accuracy (degrees) | ±0.5 |
| Lubrication | Not Required (When lubricating, use Turbine Oil ISO VG32) |
| Vacuum port pressure | Pressurization from the vacuum port should only be done during vacuum break. Also, use a breaking pressure at that time that is below the cylinder Operating Pressure. |
| Ambient Temperature | When using MVC with solid state switch, please use at an Ambient Temperature of 40°C or less. |
| Non-rotating accuracy | This is the initial value at the retraction end. |