Model: MEVT-P70
This thin electro pneumatic regulator uses a reduced wiring manifold. It operates with clean compressed air and offers two pressure control ranges.
| Working fluid | Clean compressed air (JIS B 8392-1 2012: Grade 1.3.2 or equivalent) |
| Max. working pressure (EVT100) | 200 kPa |
| Max. working pressure (EVT500) | 0.7 MPa |
| Min. working pressure | Control pressure + max. control pressure × 0.1 |
| Pressure control range (EVT100) | 0 to 100 kPa |
| Pressure control range (EVT500) | 0 to 0.5 MPa |
| Power supply voltage | 24 VDC ± 10% (stabilized power supply with ripple rate 1% or less) |
| Current consumption | 0.1 A or less |
| Hysteresis (ambient temperature 25 ± 3°C, no load, working pressure EVT100: 110 kPa / EVT500: 0.55 MPa, control pressure 10 to 100%, limited to a closed circuit on the secondary side, pressure may fluctuate during air blowing) | 0.4% F.S. or less |
| Linearity (ambient temperature 25 ± 3°C, no load, working pressure EVT100: 110 kPa / EVT500: 0.55 MPa, control pressure 10 to 100%, limited to a closed circuit on the secondary side, pressure may fluctuate during air blowing) | ±0.5% F.S. or less |
| Resolution (ambient temperature 25 ± 3°C, no load, working pressure EVT100: 110 kPa / EVT500: 0.55 MPa, control pressure 10 to 100%, limited to a closed circuit on the secondary side, pressure may fluctuate during air blowing) | 0.1% F.S. or less |
| Repeatability (ambient temperature 25 ± 3°C, no load, working pressure EVT100: 110 kPa / EVT500: 0.55 MPa, control pressure 10 to 100%, limited to a closed circuit on the secondary side, pressure may fluctuate during air blowing) | 0.3% F.S. or less |
| Step response: No load (max. working pressure, change from 50% F.S. to 100% F.S., 60% F.S., or 40% F.S.) | 0.1 s or less |
| Ambient temperature | 5 to 50°C |
| Fluid temperature | 5 to 50°C |
| Main dimensions | W14 × D75 × H75 |
| Port size | Push-in fitting ø4, ø6 (selection) |
| Weight (main body) | 80 g |
| Characteristic measurement conditions | Power supply voltage 24 ± 0.1 VDC, measured at room temperature |