Model: R※※00-P5 / P7
The P70/P74 regulators use compressed air and have exhaust treatment for cleanroom applications. The set pressure range is 0.05 to 0.85 MPa with a nonrelief design.
| Working fluid | Compressed air |
| Max. working pressure (MPa) | 1.0 |
| Proof pressure (MPa) | 1.5 |
| Ambient temperature/fluid temperature (°C) | 5 to 50 |
| Set pressure (MPa) | 0.05 to 0.85 |
| Pressure relief | Nonrelief |
| Weight, R2000 (kg) | 0.29 |
| Weight, R3000 (kg) | 0.51 |
| Weight, R4000 (kg) | 0.75 |
| Weight, R6000 (kg) | 1.1 |