CKD AB31/AB42 Direct Acting 2-Port Solenoid Valve (General Purpose, NC/NO)

AB31 is NC (open when energized) and AB42 is NO (closed when energized) in this direct acting poppet 2-port solenoid valve series. It is used for air, low vacuum, water, kerosene and oil, with hot water and steam as options. AB31 has Rc1/8 and Rc1/4 ports, and AB42 has Rc1/4 and Rc3/8 ports.

CKD AB31/AB42 Direct Acting 2-Port Solenoid Valve (General Purpose, NC/NO)CKD AB31/AB42 Direct Acting 2-Port Solenoid Valve (General Purpose, NC/NO) 2

Specifications

Working FluidAir / low vacuum (1.33×10² Pa (abs)) / water / kerosene / oil (50 mm²/s or less) (options: hot water, steam)
Valve StructureDirect acting poppet, NC (AB31) / NO (AB42)
Working Pressure DifferentialAB31: 0 to 2.5 MPa, AB42: 0 to 2.0 MPa (refer to max. working pressure differential in individual specifications)
Max. Working PressureAB31: 5 MPa, AB42: 2 MPa (1 MPa for steam option)
Proof Pressure25 MPa (water pressure)
Fluid Temperature-10 to 60 °C (options: hot water -10 to 90 °C, steam -10 to 184 °C)
Ambient Temperature-20 to 60 °C (option -20 to 100 °C)
Thermal ClassClass 130 (B) (option Class 180 (H))
Valve Seat Leakage0.2 cm³/min (ANR) or less (air) (steam option 300 or less)
Body/Seal MaterialCopper alloy / NBR (options: copper alloy / EPM rubber, copper alloy / PTFE)
Port SizeAB31: Rc1/8, Rc1/4; AB42: Rc1/4, Rc3/8
Orifice SizeAB31: 1.5 to 5 mm; AB42: 1.5 to 7 mm
WeightAB31: 0.35 kg; AB42: 0.50 kg (Rc1/4), 0.52 kg (Rc3/8)
Mounting OrientationUnrestricted
Rated Voltage100 VAC, 200 VAC, 12 VDC, 24 VDC, 48 VDC, 100 VDC (100 VAC also usable at 110 VAC (60 Hz), 200 VAC also usable at 220 VAC (60 Hz))