AD21 is a pilot operated 2-port solenoid valve that is NC (open when energized), and AD22 is NO (closed when energized). It has a diaphragm-driven pilot operated poppet structure for air, water, kerosene and oil, with Rc1 1/4 to Rc2 ports and 32 to 50 flanges.


| Working Fluid | Air / water / kerosene / oil (50 mm²/s or less) |
| Valve Structure | Pilot operated poppet, diaphragm drive, NC (AD21) / NO (AD22) |
| Working Pressure Differential | 0.02 to 0.7 MPa (AD22 0.5 MPa or less) |
| Max. Working Pressure | 1 MPa |
| Proof Pressure | 3.2 MPa (water pressure) |
| Fluid Temperature | -10 to 60 °C (no freezing) |
| Ambient Temperature | -10 to 60 °C |
| Thermal Class | Class 130 (B) |
| Valve Seat Leakage | 1 cm³/min (ANR) or less (air) |
| Body/Seal Material | Bronze / NBR |
| Port Size | Rc1 1/4, Rc1 1/2, Rc2 / 32, 40, 50 flange |
| Orifice Size | 35, 43, 53 mm (port 32, 40, 50A in order) |
| Weight | Threaded 3.5 / 4.5 / 6 kg, flanged 7 / 8 / 10 kg (32 / 40 / 50 in order) |
| Mounting Orientation | Unrestricted (within working pressure differential range) |
| Rated Voltage | 100 VAC, 200 VAC, 12 VDC, 24 VDC, 48 VDC, 100 VDC (100 VAC also usable at 110 VAC (60 Hz), 200 VAC also usable at 220 VAC (60 Hz)) |