CKD AD21EX4 Explosion-Proof Pilot Operated 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC)

AD21EX4 is a diaphragm drive pilot operated poppet 2-port solenoid valve with pressure and explosion proof construction (Ex d IIB T4), an NC type that opens when energized. It is used for air, water, kerosene and oil, with ports from Rc1 1/4 to Rc2 and 32 to 50 flange.

CKD AD21EX4 Explosion-Proof Pilot Operated 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC)CKD AD21EX4 Explosion-Proof Pilot Operated 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC) 2

Specifications

Working FluidAir / water / kerosene / oil (50 mm²/s or less)
Valve StructurePilot operated poppet, diaphragm drive, NC (open when energized)
Explosion ProtectionPressure and explosion proof construction Ex d IIB T4 (group IIB / temperature class T4)
Explosion-Proof Certification BodiesJapan certification (TIIS) or Korea certification (KOSHA), selected by order code (blank = TIIS, KR = KOSHA)
Certification NumbersAC coil (class 180 (H)): Japan No. TC20594 / Korea 16-AV4BO-0150X; DC coil and diode integrated AC coil (class 130 (B)): Japan No. TC20618 / Korea 16-AV4BO-0147X
AtmosphereOutdoors / explosive gas (group IIB / temperature class T4)
Working Pressure Differential0.02 to 0.7 MPa (refer to max. working pressure differential by model)
Max. Working Pressure1 MPa
Proof Pressure3.2 MPa (water pressure)
Fluid Temperature-10 to 60 °C (no freezing)
Ambient Temperature-10 to 50 °C
Coil Thermal ClassAC coil class 180 (H), DC coil class 130 (B), AC diode integrated coil class 130 (B)
Valve Seat Leakage1 cm³/min or less (air, measured at 0.02 to 0.7 MPa)
Degree of ProtectionIP65 or equivalent
Mounting OrientationFree (within working pressure differential range)
Port Size32A: Rc1 1/4, 32F: 32 flange, 40A: Rc1 1/2, 40F: 40 flange, 50A: Rc2, 50F: 50 flange (JIS B2210 10K flange; the companion flange is not enclosed with the product and must be purchased separately)
Min. Working Pressure Differential0.02 MPa
Max. Working Pressure Differential (MPa)Air AC 0.7 / DC 0.6, water and kerosene AC 0.7 / DC 0.6, oil AC 0.6 / DC 0.6 (all models; the DC column also applies to the diode integrated coil on AC power)
Flow Characteristics-32A and -32F: orifice ø35 mm, Cv 25, effective cross-sectional area 460 mm²; -40A and -40F: ø43 mm, Cv 34, 625 mm²; -50A and -50F: ø53 mm, Cv 53, 975 mm²
Body / Seal MaterialBody: bronze (standard) or stainless steel; seal: NBR (standard) or FKM; oil-prohibited treatment options are available (combinations H, J, L, M)
CoilCode 3: thermal class 130 (B) explosion-proof coil (for DC); code 4: thermal class 180 (H) explosion-proof coil (for AC); code 5: thermal class 130 (B) diode integrated explosion-proof coil (for AC)
Applicable Cable O.D.ø7.5 to ø9.5 / ø9.5 to ø10.5 / ø10.5 to ø11.5 / ø11.5 to ø13.5 (order codes 9 / 10 / 11 / 13)
OptionsManual override (locking)
Rated Voltage100 VAC 50/60 Hz, 200 VAC 50/60 Hz (options: 12 VDC, 24 VDC, 48 VDC, 100 VDC)
Apparent Power / Power ConsumptionApparent power: holding 18 VA (50 Hz) / 15 VA (60 Hz), starting 29 VA (50 Hz) / 24 VA (60 Hz); power consumption: AC 50/60 Hz 8/7 W, DC 11.6 W
Weight32A: 4.0 kg, 32F: 7.5 kg, 40A: 5.0 kg, 40F: 8.5 kg, 50A: 6.5 kg, 50F: 10.5 kg