CKD ADK11EX4 Explosion-Proof Pilot Kick 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC)

ADK11EX4 is a diaphragm drive pilot kick 2-port solenoid valve with pressure and explosion proof construction (Ex d IIB T4). It is an NC type that opens when energized, used for air, low vacuum, water, kerosene and oil, with Rc1/2, Rc3/4 and Rc1 ports.

CKD ADK11EX4 Explosion-Proof Pilot Kick 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC)CKD ADK11EX4 Explosion-Proof Pilot Kick 2-Port Solenoid Valve (General Purpose, Diaphragm Drive, NC) 2

Specifications

Working FluidAir / low vacuum [1.33×10³ Pa] / water / kerosene / oil (50 mm²/s or less)
Valve StructurePilot kick poppet, diaphragm drive, NC (open when energized)
Explosion ProtectionPressure and explosion proof construction Ex d IIB T4 (group IIB / temperature class T4)
Explosion-Proof Certification BodiesJapan certification (TIIS) or Korea certification (KOSHA), selected by order code (blank = TIIS, KR = KOSHA)
Certification NumbersAC coil (class 180 (H)): Japan No. TC20592 / Korea 16-AV4BO-0152X; DC coil and diode integrated AC coil (class 130 (B)): Japan No. TC20616 / Korea 16-AV4BO-0148X
AtmosphereOutdoors / explosive gas (group IIB / temperature class T4)
Working Pressure Differential0 to 1 MPa (refer to max. working pressure differential by model)
Max. Working Pressure2 MPa
Proof Pressure4 MPa (water pressure)
Fluid Temperature-10 to 60 °C (no freezing) (5 to 60 °C when the seal material is FKM)
Ambient Temperature-10 to 50 °C
Coil Thermal ClassAC coil class 180 (H), DC coil class 130 (B), AC diode integrated coil class 130 (B)
Valve Seat Leakage1 cm³/min (ANR) or less (air, measured at 0.02 to 1 MPa). The seal may be unstable below 0.02 MPa: inquire separately
Degree of ProtectionIP65 or equivalent
Mounting OrientationUnrestricted
Port Size / Orifice SizeADK11EX4-15A: Rc1/2, ø16 mm; -20A: Rc3/4, ø23 mm; -25A: Rc1, ø28 mm
Min. Working Pressure Differential0 MPa
Max. Working Pressure Differential (MPa)Air AC 1 / DC 0.6, water and kerosene AC 1 / DC 0.6, oil AC 0.6 / DC 0.5 (all models; the DC column also applies to the diode integrated coil on AC power)
Flow Characteristics-15A: C 20 dm³/(s·bar), b 0.31, Cv 4.5; -20A: Cv 8.6, effective cross-sectional area 162 mm²; -25A: Cv 12.0, effective cross-sectional area 231 mm²
Body / Seal MaterialBody: bronze (standard) or stainless steel; seal: NBR (standard), FKM, EPM rubber (ethylene propylene rubber, oil-prohibited treatment option). The max. working pressure differential of the ethylene propylene rubber combination is 0.6 MPa, and it cannot be used with air (compressed air contains oil and ethylene propylene rubber is not oil-resistant)
CoilCode 3: thermal class 130 (B) explosion-proof coil (for DC); code 4: thermal class 180 (H) explosion-proof coil (for AC); code 5: thermal class 130 (B) diode integrated explosion-proof coil (for AC)
Applicable Cable O.D.ø7.5 to ø9.5 / ø9.5 to ø10.5 / ø10.5 to ø11.5 / ø11.5 to ø13.5 (order codes 9 / 10 / 11 / 13)
Rated Voltage100 VAC 50/60 Hz, 200 VAC 50/60 Hz (options: 12 VDC, 24 VDC, 48 VDC, 100 VDC)
Apparent Power / Power ConsumptionApparent power: holding 20 VA (50 Hz) / 16 VA (60 Hz), starting 80 VA (50 Hz) / 64 VA (60 Hz); power consumption: AC 50/60 Hz 10/8.5 W, DC 15 W
Weight-15A: 1.4 kg, -20A: 1.5 kg, -25A: 1.9 kg
Use at Low VacuumApply the vacuum to the OUT port side