GEXA is the manifold version of EXA, an NC pilot operated 2-port solenoid valve. It is dedicated to compressed air with common supply (port C pressurization), and its A ports are ø6 to ø12 push-in fittings.


| Working Fluid | Compressed air |
| Valve Structure | Pilot operated diaphragm drive, NC, common supply (port C pressurization) |
| Working Pressure Differential | 0.01 to 0.7 MPa |
| Max. Working Pressure | 0.7 MPa |
| Proof Pressure | 1.05 MPa (water pressure) |
| Fluid Temperature | 0 to 55 °C (no freezing) |
| Ambient Temperature | -5 to 55 °C |
| Atmosphere | Place free of corrosive gas and explosive gas and not exposed to water |
| Internal Leakage | 2 cm³/min or less (per station) |
| External Leakage | 3 cm³/min or less (per station) |
| Port Size | A port: push-in fitting ø6, ø8, ø10, ø12 (C port: push-in fitting ø10, ø12) |
| Flow Characteristic C | 1.6 / 3.0 / 3.3 / 3.6 dm³/(s·bar) (ø6 / ø8 / ø10 / ø12) |
| Mounting Orientation | Unrestricted |
| Rated Voltage | 100 VAC (50/60 Hz), 24 VDC, 12 VDC |
| Power Consumption | AC 1.2 VA, DC 0.6 W |
| Thermal Class | Class 130 (B) |
| Degree of Protection | Lead wire: IPX0, with DIN terminal box: IPX5 |