CKD GFWB Direct Acting 2-Port Solenoid Valve for Water, Manifold (Special Purpose)

GFWB is an NC direct acting 2-port manifold solenoid valve dedicated to water. It uses common water supply (port C pressurization), with Rc1/8 and Rc1/4 A ports and Rc1/4 and Rc3/8 C ports. It is not for sewage, agricultural water or liquid manure.

CKD GFWB Direct Acting 2-Port Solenoid Valve for Water, Manifold (Special Purpose)CKD GFWB Direct Acting 2-Port Solenoid Valve for Water, Manifold (Special Purpose) 2

Specifications

Working FluidWater (excluding sewage, agricultural water and liquid manure)
Valve StructureDirect acting poppet, NC, manifold, common water supply (port C pressurization)
Working Pressure Differential0 to 1.5 MPa (refer to the max. working pressure differential in the individual specifications)
Proof Pressure5.0 MPa (3.0 MPa for ø7 orifice) (water pressure)
Fluid TemperatureAC 1 to 60 °C, DC 1 to 40 °C (no freezing)
Ambient Temperature-20 to 40 °C
Thermal ClassClass 130 (B)
Valve Seat Leakage0 cm³/min (water pressure)
Degree of ProtectionIP65 or equivalent (IP61 or equivalent for T type terminal box)
Port SizeA port: Rc1/8, Rc1/4; C port: Rc1/4, Rc3/8
Orifice Size1~7 mm
Mounting OrientationUnrestricted
Rated Voltage100 VAC, 200 VAC, 24 VDC, 12 VDC (100 VAC also usable at 110 VAC (60 Hz), 200 VAC also usable at 220 VAC (60 Hz))