Model: W4GA/B/Z2・MW4GA/B/Z2
Discontinuing (2027-02-26)
This is a plug-in block manifold. The MW4GA2-R1 uses body piping and individual-wiring I/O connectors.
| Manifold type (MW4GA2-R1) | Block manifolds |
| Supply and exhaust method (MW4GA2-R1) | Common supply and exhaust (Built-in malfunction prevention valve) |
| Valve type and actuation method (MW4GA2-R1) | Pilot operated soft spool valve |
| Working fluid (MW4GA2-R1) | Compressed Air |
| Maximum working pressure (MW4GA2-R1, MPa) | 0.7 |
| Minimum working pressure (MW4GA2-R1, Internal pilot, MPa) | 0.2 |
| Proof pressure (MW4GA2-R1, MPa) | 1.05 |
| Ambient temperature (MW4GA2-R1, ℃) | -5~55(No freezing) |
| Fluid temperature (MW4GA2-R1, ℃) | 5 to 55 |
| Manual override (MW4GA2-R1) | Combined non-locking and locking type (Standard) |
| Lubrication (MW4GA2-R1) | Not required |
| Protection structure (MW4GA2-R1) | Dust-resistant and jet-proof (Equivalent to IP65) |
| Vibration resistance (MW4GA2-R1, m/s2) | 49 or less |
| Shock resistance (MW4GA2-R1, m/s2) | 294 or less |
| Rated voltage (MW4GA2-R1, V DC) | 12, 24 |
| Voltage fluctuation range (MW4GA2-R1) | ±10% |
| Holding current (MW4GA2-R1, DC24V, A) | 0.025 |
| Power consumption (MW4GA2-R1, DC24V, W) | 0.6 |
| Maximum number of stations (MW4GA2-R1) | 16 |