MFC FLOW MF-400C Mass Flow Controller (Analog)

MFC FLOW MF-400C Mass Flow Controller (Analog)MFC FLOW MF-400C Mass Flow Controller (Analog) 2

Specifications

Flow Range (N2 basis)100~200 SLM
Accuracy≤2.0% of Full Scale
Linearity≤0.5% of Full Scale
Response Time≤2sec
Power Supply+15Vdc or +24Vdc / Max. 300mA
Material (wetted parts)SUS 316L
Flow Control Range2~100% of Full Scale
Repeatability≤±0.2% of Full Scale
Operating Temperature0~50°C (guaranteed accuracy 15~35°C)
Working PressureInquiry
Leak Rate1x10^-8 Pa.m3/sec (He)
Seal MaterialFKM (Viton)/H-NBR(Buna)/FFKM(Kalrez)/Teflon/EPDM
ControlNormally Closed Solenoid
ConnectorD-Sub 9 Pin Male
FittingsLOK 1/4",3/8",1/2" VCR 1/4",1/2"
InterfaceAnalog