ExPolar Heating System

Model: ExPolar

A heating system fitted over ExMax explosion-proof electric actuators so they can be used at low ambient temperatures. It consists of a heater, thermostat, insulation, stainless steel enclosure and an explosion-proof terminal box.

Features

ExPolar Heating System ExPolarExPolar Heating System ExPolar 2

Specifications

Supply Voltage / Frequency24 V AC/DC, 48 V AC/DC, 120 V AC or 240 V AC, 50/60 Hz with AC
Current Consumption24 V: 2.5 A (protection class III, grounded); 48 V: 1.3 A (protection class I, grounded); 120 V: 0.5 A (protection class I, grounded); 240 V: 0.3 A (protection class I, grounded)
Rated Output60 W ±5%
Electrical ConnectionEx-e terminal box with terminals 0.5 to 4 mm², equipotential bonding 4 mm²
Cable GlandM20 × 1.5 mm, cable bushing Ø 6~13 mm
Enclosure MaterialStainless steel 1.4404 / UNS S31603 / AISI 316L
Heater / Thermostat MaterialAluminium, seawater-resistant galvanised, NBR gasket
Terminal Box MaterialAluminium, powder-coated, EPDM gasket
InsulationArmacell/HT
WeightMS type approx. 1.9 kg, MM type approx. 2.2 kg, CBR type approx. 1.8 kg
Storage Temperature-50 to +60 °C
Ambient Temperature (operating)-50 to +60 °C
Humidity0 to 90% RH, non-condensing
Preheat TimeApprox. 1 hour
Thermostat FunctionON/OFF: TR = -10 °C / 0 °C
Temperature MonitoringON/OFF: T1lim = +60 °C / +15 °C, T2lim = +70 °C / +5 °C
Operating Mode100% ED (duty cycle)
Scope of DeliveryHeating system with insulation, including heating element, control thermostat, terminal box and securing elements
Status on DeliveryPrefitted terminal box (MS type: right; MM and CBR types: left)
Enclosure ProtectionIP66 per EN 60529
Explosion Protection (gas)II 2 G Ex eb mb IIC T6
Explosion Protection (dust)II 2 D Ex tb mb IIIC T80°C
Operating Temperature-50~60 °C
Body MaterialStainless steel

Request a Quote