Vacuum Right Angle Valve (SUS304, Manual, Bellows Seal)

Model: PVV-03

PVV-03 is a manual vacuum right-angle valve with a bellows-seal construction, supporting a size range from NW16 up to NW160. With the stem drive isolated from the atmosphere by a metal bellows that separates the stem seal from outside air, and 100% helium leak tested prior to shipment, it is used for chamber-isolation and pump-shutoff applications in high-vacuum (HV) environments.

Features

Vacuum Right Angle Valve (SUS304, Manual, Bellows Seal) PVV-03

Specifications

End ConnectionKF, MF
MaterialSS304
Ball/Disc MaterialSS304
Seat MaterialSS316, VITON, PTFE
OperationKnob
OriginSouth Korea
SizeNW16, NW25, NW40, NW50, NW63, NW80, NW100, NW160, MF63, MF80, MF100, MF160

Frequently Asked Questions

How do I distinguish between angle valves and inline valves?
Angle valves have a flow path that bends 90 degrees, suitable for direct connection to pumps and chambers to reduce piping length or connect vertical and horizontal piping. Inline valves have a straight flow path, used by inserting in the middle of straight piping for line interruption purposes. For pump shutoff and other installations directly below chambers, angle valves are usually more suitable.
How is the bellows seal life determined?
Standard specifications are designed targeting approximately 10,000 or more open/close cycles. However, actual life varies with operating frequency, differential pressure, operating temperature, and gas type, so for lines expecting high-frequency automatic cycles, let us know the conditions and we will propose high-cycle specifications or regular replacement plans.
What level of vacuum can it be used to?
PVV-03 is designed for line isolation and pump shutoff in the high vacuum (HV) range. The actual achievable vacuum varies greatly with chamber volume, pumping system configuration, operating temperature, and gas type, and separate specification review is required for environments requiring ultra-high vacuum (UHV). Let us know your operating environment and we will guide you on suitability and options.
How should I select the NW size?
Sizes are generally determined based on chamber volume and target pumping time. Since angle valves are often installed on the pump inlet side, provide your pump connection flange specification and target exhaust conductance and we will review the appropriate size.