Model: AMD3※3R
This air operated valve for rechargeable battery manufacturing processes handles chemical liquids, pure water, air and N2 gas. Normal and bypass bodies are available, and the diaphragm is made of PTFE.
| Working fluid | Chemical liquids, pure water, air, N2 gas |
| Fluid temperature (normal body; except hydrofluoric acid and F-LOCK60, °C) | 5 to 120 |
| Fluid temperature (hydrofluoric acid or liquids containing it, °C) | 5 to 80 |
| Fluid temperature (F-LOCK60 Series fitting, °C) | 5 to 100 |
| Fluid temperature (bypass body; not for hydrofluoric acid, °C) | 5 to 90 |
| Proof pressure (MPa) | 1.0 |
| Working pressure (A→B, normal body, MPa) | 0 to 0.5 |
| Working pressure (B→A, normal body, MPa) | 0 to 0.5 |
| Valve seat leakage (cm3 /min) | 0 (water pressure) |
| Back pressure (normal body, MPa) | 0 to 0.5 |
| Ambient temperature (°C) | 0 to 60 |
| Ambient temperature (sensor attached, °C) | 0 to 50 |
| Frequency | 30 cycles/min. or less |
| Mounting orientation | Unrestricted |
| Operating pressure (NC/NO, MPa) | 0.35 to 0.5 |
| Operating pressure (double acting, MPa) | 0.3 to 0.4 |
| Operating port | Rc1/8 |
| Weight (normal body, kg) | 0.21 |
| Weight (bypass body, kg) | 0.23 |