CKD VSECV Position Locking Valve

Model: VSECV

The VSECV is a position locking valve that holds vacuum to keep a workpiece gripped. It works at a positive pressure of 0 to 0.7 MPa and a negative pressure of -100 to 0 kPa, with M3 to M10 and R1/8 ports.

CKD VSECV Position Locking Valve VSECVCKD VSECV Position Locking Valve VSECV 2

Specifications

Working FluidAir
Working Pressure (positive pressure)0 to 0.7 MPa
Working Pressure (negative pressure)-100 to 0 kPa
Ambient Operating Temperature0 to 60 °C
Port SizeM3, M4, M5, M6, M10, R1/8

Frequently Asked Questions

What happens when a pad separates from the workpiece?
Its valve restricts the suction passage to reduce vacuum loss at other pads. A small intake flow is needed for valve operation.
Is it a check valve for vacuum holding?
It is not a check valve and must not be used for vacuum holding. Vacuum is not held unless the vacuum source has a holding function.
What are the working fluid and ambient temperature range?
The working fluid is air and the ambient operating temperature is 0 to 60 °C.
How is the number of valves determined?
Compare the minimum working intake flow per valve with the ejector intake flow. Confirm operation with the actual equipment.

Request a Quote