CKD LGD1*/LGD2* Air Operated Valve for Process Gas (Metal Diaphragm, NC/NO)

LGD1* and LGD2* are air operated valves with a metal diaphragm for inert gas and process gas. NC and NO can be selected. LGD1* has 1/4" connections, and LGD2* has 3/8" and 1/2" connections.

CKD LGD1*/LGD2* Air Operated Valve for Process Gas (Metal Diaphragm, NC/NO)CKD LGD1*/LGD2* Air Operated Valve for Process Gas (Metal Diaphragm, NC/NO) 2

Specifications

Working FluidInert gas / process gas
Working Pressure1.3×10⁻⁸ Pa(abs) to 0.99 MPa(G)
Fluid Temperature5 to 80 °C
Ambient Temperature5 to 80 °C
Valve Seat Leakage1.0×10⁻¹⁰ Pa·m³/sec He or less
External Leakage1.0×10⁻¹⁰ Pa·m³/sec He or less
Cv (23 °C under pressurization)LGD1*: 0.3; LGD2*: 3/8" 0.65, 1/2" 0.7
ConnectionLGD1*: 1/4" JXR male fitting or equiv. (4RM) / 1/4" JXR female fitting or equiv. (4R) / 1/4" double barbed fitting (4S); LGD2*: 1/2" JXR male fitting or equiv. (3/8" compatible) (8RM) / 1/2" JXR female fitting or equiv. (3/8" compatible) (8R) / 3/8" double barbed fitting (6S) / 1/2" double barbed fitting (8S) (JXR fitting can be connected to VCR fitting)
ActuationNC (order code 1) / NO (2)
Operating PressureNC: 0.4 to 0.6 MPa; NO: 0.4 to 0.5 MPa
Operating PortM5
Weight (with JXR male fitting or equiv.)LGD1*: 0.23 kg; LGD2*: 0.57 kg
Gas Contact Part MaterialsDiaphragm: Ni-Co alloy; valve seat: PCTFE; body: SUS316L