Model: PNA-FP2
PNA-FP2 is an inline oxygen monitor that measures oxygen concentration under pressure. Its modular, pressure-resistant structure connects to the NS nitrogen gas extraction unit and F.R units without gas purging.
| Measurement method | Zirconia solid electrolyte method |
| Sampling method | Natural diffusion |
| Fluid | Nitrogen-enriched compressed air |
| Working pressure (MPa) | 0~1.0 |
| Proof pressure (MPa) | 1.5 |
| Ambient temperature , Humidity | 0~50°C, 80%RH or less ( No condensation ) |
| Fluid temperature | 0~50°C( No condensation ) |
| Storage ambient temperature, humidity | -10~60°C, 80%RH or less ( No condensation ) |
| Maximum flow rate (L/min(ANR)) | 500 |
| Measurement range (%O2) | 0.00~25.00 |
| Response time (flow rate 5L/min(ANR) or more) | 90% response within 20s |
| Analog Output | 4~20mA current output (for 0.00~25.00%O2) |
| Analog output load resistance | 0~400Ω |
| Switch output capacity | 24V DC, 1A |
| Supply Voltage | 24V DC ±15% (when using AC adapter: AC100V~AC240V) |
| Power Consumption | 10W or less |
| Degree of protection | IP65 Equivalent |
| Weight (kg) | 1.6 |
| Port size | Rc3/8 / G3/8 / NPT3/8 |