CKD SW-T-P4 Cylinder switch, P4* Series for Rechargeable battery manufacturing processes

Model: SW-T-P4※

This general-purpose cylinder switch belongs to the P4 series for rechargeable battery manufacturing processes. It can be mounted on many cylinders and is available in solid state 2-wire, 3-wire and reed models.

Features

CKD SW-T-P4 Cylinder switch, P4* Series for Rechargeable battery manufacturing processes SW-T-P4※CKD SW-T-P4 Cylinder switch, P4* Series for Rechargeable battery manufacturing processes SW-T-P4※ 2

Specifications

Applicable CylinderSCPD3, CMK2, SCM, SCG, SCS2, SCA2, SSD, SSD2, SSG, STK, ILK, USSD, STG, STS/STL, LCR, LCG, UCA2, SRL3, SRM3, MRL2, MRG2, GRC, LSH-HP, HAP, BHA, LHS/LHAG, BHG, HKP, HCP, HMF, HLC, HLD, HLF2, HMD, BHE, CKG, CKL2, CKLB2, CKF, AVB
Switch type (T1, T2)Solid state 2-wire type
Switch type (T3)Solid state 3-wire type
Switch type (T0, T5, T8)Reed 2-wire type
Output method (T3)NPN output
Power supply voltage (T3, VDC)10 to 28
Load voltage (T1, VAC)85 to 265
Load voltage (T2, VDC)10 to 30
Load voltage (T3)30 VDC or less
Load voltage (T0, T8, DC)12/24 VDC
Load voltage (T5, DC)5/12/24 VDC
Load voltage (T0, T5, T8, AC 110 V)110 VAC
Load voltage (T8, AC 220 V)220 VAC
Load current (T1, mA)5 to 100
Load current (T2, mA)5 to 20
Load current (T3)100 mA or less
Load current (T0, T8, DC, mA)5 to 50
Load current (T5, DC)50 mA or less
Current consumption (T3)10 mA or less (at 24 VDC)
Internal voltage drop (T1)10% or less of load voltage
Internal voltage drop (T2)4 V or less
Internal voltage drop (T3)0.5 V or less
Indicator Lamp (T1, T2, T3, T0, T8)Red LED (Lights up when ON)
Indicator Lamp (T5)None
Leakage current (T1)1 mA or less (100 VAC), 2 mA or less (200 VAC)
Leakage current (T2)1 mA or less
Leakage current (T3)10 μA or less
Leakage current (T0, T5, T8)0 mA
Lead wire length (T1, T8)1 m (Oil-resistant vinyl cabtyre cord 2-core 0.3 mm²)
Lead wire length (T2, T0, T5)1 m (Oil-resistant vinyl cabtyre cord 2-core 0.2 mm²)
Lead wire length (T3)1 m (Oil-resistant vinyl cabtyre cord 3-core 0.2 mm²)
Shock resistance (T1, T2, T3)980 m/s²
Shock resistance (T0, T5, T8)294 m/s²
Insulation resistance (T1, T8)100 MΩ or more with 500 VDC megger
Insulation resistance (T2, T3, T0, T5)20 MΩ or more with 500 VDC megger
Dielectric strength (T1, T8)No abnormality when 1500 VAC is applied for 1 minute
Dielectric strength (T2, T3, T0, T5)No abnormality when 1000 VAC is applied for 1 minute
Ambient Temperature (°C)-10 to +60
Protection structureIEC standard IP67, JIS C0920 (Immersible type)
Contact protection circuit (T0, T5)None
Contact protection circuit (T8)Yes
Weight (T1, T8)1 m: 33 g, 3 m: 87 g, 5 m: 142 g
Weight (T2, T3, T0, T5)1 m: 18 g, 3 m: 49 g, 5 m: 80 g

Request a Quote