Model: SW-T-P4※
This general-purpose cylinder switch belongs to the P4 series for rechargeable battery manufacturing processes. It can be mounted on many cylinders and is available in solid state 2-wire, 3-wire and reed models.
| Applicable Cylinder | SCPD3, CMK2, SCM, SCG, SCS2, SCA2, SSD, SSD2, SSG, STK, ILK, USSD, STG, STS/STL, LCR, LCG, UCA2, SRL3, SRM3, MRL2, MRG2, GRC, LSH-HP, HAP, BHA, LHS/LHAG, BHG, HKP, HCP, HMF, HLC, HLD, HLF2, HMD, BHE, CKG, CKL2, CKLB2, CKF, AVB |
| Switch type (T1, T2) | Solid state 2-wire type |
| Switch type (T3) | Solid state 3-wire type |
| Switch type (T0, T5, T8) | Reed 2-wire type |
| Output method (T3) | NPN output |
| Power supply voltage (T3, VDC) | 10 to 28 |
| Load voltage (T1, VAC) | 85 to 265 |
| Load voltage (T2, VDC) | 10 to 30 |
| Load voltage (T3) | 30 VDC or less |
| Load voltage (T0, T8, DC) | 12/24 VDC |
| Load voltage (T5, DC) | 5/12/24 VDC |
| Load voltage (T0, T5, T8, AC 110 V) | 110 VAC |
| Load voltage (T8, AC 220 V) | 220 VAC |
| Load current (T1, mA) | 5 to 100 |
| Load current (T2, mA) | 5 to 20 |
| Load current (T3) | 100 mA or less |
| Load current (T0, T8, DC, mA) | 5 to 50 |
| Load current (T5, DC) | 50 mA or less |
| Current consumption (T3) | 10 mA or less (at 24 VDC) |
| Internal voltage drop (T1) | 10% or less of load voltage |
| Internal voltage drop (T2) | 4 V or less |
| Internal voltage drop (T3) | 0.5 V or less |
| Indicator Lamp (T1, T2, T3, T0, T8) | Red LED (Lights up when ON) |
| Indicator Lamp (T5) | None |
| Leakage current (T1) | 1 mA or less (100 VAC), 2 mA or less (200 VAC) |
| Leakage current (T2) | 1 mA or less |
| Leakage current (T3) | 10 μA or less |
| Leakage current (T0, T5, T8) | 0 mA |
| Lead wire length (T1, T8) | 1 m (Oil-resistant vinyl cabtyre cord 2-core 0.3 mm²) |
| Lead wire length (T2, T0, T5) | 1 m (Oil-resistant vinyl cabtyre cord 2-core 0.2 mm²) |
| Lead wire length (T3) | 1 m (Oil-resistant vinyl cabtyre cord 3-core 0.2 mm²) |
| Shock resistance (T1, T2, T3) | 980 m/s² |
| Shock resistance (T0, T5, T8) | 294 m/s² |
| Insulation resistance (T1, T8) | 100 MΩ or more with 500 VDC megger |
| Insulation resistance (T2, T3, T0, T5) | 20 MΩ or more with 500 VDC megger |
| Dielectric strength (T1, T8) | No abnormality when 1500 VAC is applied for 1 minute |
| Dielectric strength (T2, T3, T0, T5) | No abnormality when 1000 VAC is applied for 1 minute |
| Ambient Temperature (°C) | -10 to +60 |
| Protection structure | IEC standard IP67, JIS C0920 (Immersible type) |
| Contact protection circuit (T0, T5) | None |
| Contact protection circuit (T8) | Yes |
| Weight (T1, T8) | 1 m: 33 g, 3 m: 87 g, 5 m: 142 g |
| Weight (T2, T3, T0, T5) | 1 m: 18 g, 3 m: 49 g, 5 m: 80 g |