Model: WCS
The WCS is a refractive-index sensor for continuous inline concentration measurement of water-soluble coolant. It measures concentration and fluid temperature, and each of its two outputs can be configured as an analog or switch output.
| Indicator | LCD display |
| Brix Measurement range | 0.0~30.0% |
| Fluid temperature Measurement range | 10~50°C |
| Brix Resolution | 0.1% |
| Fluid temperature Resolution | 0.1°C |
| Brix Measurement accuracy (0.0~30.0% Range) | ±1.0% |
| Fluid temperature Measurement accuracy | ±2.0°C |
| Brix Display range | ー2.0~33.0% |
| Working Pressure | 0~1.0MPa |
| Proof Pressure | 1.5MPa |
| Ambient Operating Temperature | 10~50°C |
| Storage temperature | 5~50°C |
| Protection Rating | IP65/IP67 (with manifold) |
| Analog output (Connected load impedance 300Ω or less) | 4~20mA |
| Switch output (Maximum load current 50mA) | NPN or PNP transistor open collector output |
| Power supply voltage (Ripple ratio 1% or less) | DC24V±10% |
| Current consumption (DC24V connected, load disconnected) | 12mA or less |
| Total weight | Approx. 1.8kg |
| Port size | Rc1/4 |
| Cable connection | 4-core flying leads |