HTC Vacuum Ball Valve

A ball valve that opens and closes a vacuum line by turning a ported ball 1/4 turn. Its simple, rugged design suits dirty vacuum service such as isolating traps and scrubbers, isolating gauges and roughing lines. Manual, pneumatic and electric actuation are available, with KF and ISO-K flanges.

HTC Vacuum Ball ValveHTC Vacuum Ball Valve 2

Specifications

Actuation TypeManual, pneumatic (1/4 turn), electric
End ConnectionKF(NW), ISO-K flange
SizeKF type 1" to 2" (25.4 to 50.8 mm)
Pressure Range2 bar to 1×10⁻⁴ mbar
Leak Rate9×10⁻⁷ mbar·l/s
MaterialSS316, PTFE
Maximum TemperatureCylinder 80 °C, body 100 °C
Compressed Air ConnectionKF25 2×1/8" NPT, KF40 and KF50 2×1/4" NPT
Compressed Air Pressure4 to 7 kgf/cm² (ISO-K pneumatic type)
Electric ModelsKF25BV107E, KF40BV130E, KF50BV151E
Power SupplyStandard 110 V (other voltages by last letter of P/N: A=AC110V, B=AC220V, C=AC220V 3-phase, D=AC380V 3-phase)
OptionsLimit switch, solenoid
Actuation TimeElectric type, full opening: 13 s at 50 Hz, 12 s at 60 Hz

Frequently Asked Questions

How does the valve open and close?
A ball with a central bore rotates a quarter turn to open or close the flow path.
What actuation types are available?
Manual, pneumatic and electric actuation types are available.
What are the maximum operating temperatures of the KF pneumatic type?
The maximum is 80 °C for the cylinder and 100 °C for the body.

Request a Quote